This is a working overview of Stationary phase, written for readers who want more than a one-paragraph summary but less than a textbook.
Reviewed 2025-12-28. Anything still debated is marked as such rather than presented as settled.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
| Property | Value | Notes |
|---|---|---|
| Accuracy | Recovery near 100% | Depends on acceptance criteria and matrix |
| Precision | Relative standard deviation | Often at or below 2% for replicate injections |
| Limit of detection | Signal-to-noise ratio 3:1 | Approximate and method-specific |
| Limit of quantitation | Signal-to-noise ratio 10:1 | Confirmed by precision and accuracy |
| Resolution | 1.5 or greater | Typical system suitability target |
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
This concern is not the same as the serotonin-toxicity risk seen when MAOIs are combined with drugs that significantly inhibit serotonin reuptake or release serotonin. A classic MAOI-to-classic MAOI overlap is not expected to cause serotonin toxicity unless another serotonergic drug with clinically significant serotonin reuptake inhibition or serotonin-releasing activity is also involved. This should be distinguished from medically supervised switching between classic MAOIs, where shorter washouts, direct switches, or cautious cross-tapering have been used by some expert clinicians under close monitoring. In that context, temporary MAOI-to-MAOI overlap may have practical utility, such as reducing relapse risk or avoiding a prolonged untreated interval when changing from one MAOI to another because of adverse effects or inadequate response. Drugs described as "stimulants" are not a uniform pharmacological category and are not uniformly contraindicated with phenelzine. Modern MAOI guidance distinguishes amphetamines by dose: medium or high doses are avoided because of serotonin-releasing activity, while low-dose amphetamines are listed as a strong relative contraindication rather than an absolute contraindication. When used by experienced clinicians, they require specialist caution, reduced starting doses, slow titration, and blood-pressure monitoring. Lisdexamfetamine may be lower risk than some other amphetamine preparations because of its lower peak plasma concentration and longer time to peak concentration.
The clinical relevance of the results published by Auchus in 2004 was demonstrated in 2012 for the first time when Kamrath et al. attributed the urinary metabolites to the androgen backdoor pathway from 17OHP to DHT in patients with steroid 21-hydroxylase (encoded by the gene CYP21A2) enzyme deficiency. Barnard et al. in 2017 demonstrated metabolic pathways from C21 steroids to 11KDHT that bypasses A4 and T, an aspect that is similar to that of the backdoor pathway to DHT. These newly discovered pathways to 11-oxygenated androgens were also described as "backdoor" pathways due to this similarity, and were further characterized in subsequent studies.
== Preparation == A blood smear is made by placing a drop of blood on one end of a slide, and using a spreader slide to disperse the blood over the slide's length. The aim is to get a region, called a monolayer, where the cells are spaced far enough apart to be counted and differentiated. The monolayer is found in the "feathered edge" created by the spreader slide as it draws the blood forward.
Sources: en.wikipedia.org
== Variants == A common variant is Lillie's trichrome, which uses aniline blue instead of a green dye. It is often erroneously called Masson's trichrome. It differs in the dyes used, their concentrations, and the immersion times. Another common variant is the Masson trichrome & Verhoeff stain, which combines the Masson trichrome stain and Verhoeff's stain. This combination is useful for the examination of blood vessels; the Verhoeff stain highlights elastin (black) and allows one to easily differentiate small arteries (which typically have at least two elastic laminae) and veins (which have one elastic lamina).
== Availability and purity == Iodine-125 is commercially available in dilute NaOH solution as 125I-iodide (or the hypohalite sodium hypoiodite, NaIO). The radioactive concentration lies at 4 to 11 GBq/mL and the specific radioactivity is > 75 GBq/μmol (7.5 × 1016 Bq/mol). The chemical and radiochemical purity is high. The radionuclidic purity is also high; some 126I (t1/2 = 12.93 d) is unavoidable due to the neutron capture noted above. The 126I tolerable content (which is set by the unwanted isotope interfering with dose calculations in brachytherapy) lies at about 0.2 atom % (atom fraction) of the total iodine (the rest being 125I).
=== Discontinuation === The British National Formulary recommends a gradual withdrawal when discontinuing antipsychotics to avoid acute withdrawal syndrome or rapid relapse. Symptoms of withdrawal commonly include nausea, vomiting, and loss of appetite. Other symptoms may include restlessness, increased sweating, and trouble sleeping. Less commonly there may be a feeling of the world spinning, numbness, or muscle pains. Symptoms generally resolve after a short period of time. There is tentative evidence that discontinuation of antipsychotics can result in psychosis. It may also result in reoccurrence of the condition that is being treated. Rarely tardive dyskinesia can occur when the medication is stopped.
Sources: en.wikipedia.org
At the end of the 1896 season, Essendon, along with seven other clubs, formed the Victorian Football League. Essendon's first VFL game was in 1897 against Geelong at Corio Oval in Geelong. Essendon won its first VFL premiership by winning the 1897 VFL finals series in a round-robin event. Essendon again won the premiership in 1901, defeating Collingwood in the Grand Final. The club won successive premierships in 1911 and 1912 over Collingwood and South Melbourne, respectively.
=== Government and NGO reports === National Drug Threat Assessment 2009 from the United States Department of Justice War On Drugs: Legislation in the 108th Congress and Related Developments, a 2003 report from the Congressional Research Service via the State Department website The Report of the Canadian Government Commission of Inquiry into the Non-Medical Use of Drugs – 1972 Drug Enforcement Administration (2017), Drugs of abuse: A DEA resource guide (PDF) (2017 ed.), Washington, D.C.: Author, archived from the original (PDF) on December 3, 2016, retrieved January 23, 2018 Revealing the missing link to Climate Justice: Drug Policy, a 2023 report from the International Coalition on Drug Policy Reform and Environmental Justice
The nucleoside cytosine has a half-life in isolation of 19 days at 100 °C (212 °F) and 17,000 years in freezing water, which some argue is too short on the geologic time scale for accumulation. Others have questioned whether ribose and other backbone sugars could be stable enough to be found in the original genetic material, and have raised the issue that all ribose molecules would have had to be the same enantiomer, as any nucleotide of the wrong chirality acts as a chain terminator. Pyrimidine ribonucleosides and their respective nucleotides have been prebiotically synthesised by a sequence of reactions that by-pass free sugars and assemble in a stepwise fashion by including nitrogenous and oxygenous chemistries. In a series of publications, John Sutherland and his team at the School of Chemistry, University of Manchester, have demonstrated high yielding routes to cytidine and uridine ribonucleotides built from small 2- and 3-carbon fragments such as glycolaldehyde, glyceraldehyde or glyceraldehyde-3-phosphate, cyanamide, and cyanoacetylene. One of the steps in this sequence allows the isolation of enantiopure ribose aminooxazoline if the enantiomeric excess of glyceraldehyde is 60% or greater, of possible interest toward biological homochirality. This can be viewed as a prebiotic purification step, where the said compound spontaneously crystallised out from a mixture of the other pentose aminooxazolines. Aminooxazolines can react with cyanoacetylene in a mild and highly efficient manner, controlled by inorganic phosphate, to give the cytidine ribonucleotides.
=== Carpet sharks === The bamboo sharks (Hemiscylliidae) and the zebra shark (Stegostomatidae) lay eggs on the bottom, while the other carpet sharks give live birth. The egg cases are oval and covered with adhesive fibers that serve to secure them to the bottom.
Sources: en.wikipedia.org
Validation establishes suitability for a new method, while verification confirms that a method works in a specific laboratory. Verification is often used when a validated method is adopted with existing equipment and staff. Both rely on documented acceptance criteria.
Quantification usually compares detector response to a standard curve made from reference standards. The curve may be external, internal, or based on standard addition depending on matrix effects. Results are reported with units and, when required, uncertainty.
Carryover occurs when analyte from a previous injection remains in the system and appears in a later chromatogram. It can come from the injector, column, or tubing. Blank injections and needle washes help detect and reduce it.
System suitability is a set of checks performed before and during an HPLC run to confirm that the instrument and method are working as expected. It may include retention time repeatability, resolution between peaks, peak symmetry, and signal intensity. Failing suitability criteria usually invalidates the run.