This is a working overview of Stationary phase, written for readers who want more than a one-paragraph summary but less than a textbook.
This page was last updated on 2026-05-14 and is reviewed periodically as new material appears.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
| Property | Value | Notes |
|---|---|---|
| Abbreviation | HPLC | Also called high-performance liquid chromatography |
| Separation mechanism | Differential partitioning | Compounds distribute between mobile and stationary phases |
| Typical column chemistry | C18 (octadecylsilane) | Used in reversed-phase separations |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is common for trace and confirmatory work |
| Typical particle size | 1.8–5 µm | Smaller particles require higher pressure and can improve speed |
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Validation establishes that a method is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, robustness, and stability of standards and samples. Acceptance criteria are defined in advance, and results are documented in a validation report. Regulatory guidance for pharmaceuticals, foods, and environmental testing differs, so the applicable framework must be identified. Ongoing verification uses control samples and trend charts after validation. Method transfer to another laboratory may require partial revalidation.
Routine quality control includes blanks, duplicates, spiked samples, and certified reference materials. Calibration curves are prepared with standards at several concentrations, and the detector response is checked for linearity. Carryover, column aging, mobile phase evaporation, and temperature drift can shift retention times or peak areas. Maintenance such as replacing seals, filters, and columns helps prevent failures. Records of injections, integration, and deviations support traceability. Audits may request raw data and instrument logs for each batch.
Developing an HPLC test begins with defining the analytes, matrix, and required reporting limits. Chemists select a separation mode, column chemistry, mobile phase composition, flow rate, and detection wavelength or mass transition. Experiments then adjust these variables to achieve adequate retention, resolution, and peak shape. System suitability tests confirm that the instrument and method perform consistently before sample analysis. Without suitable resolution, quantitative results may be unreliable. Preliminary runs often use scouting gradients to locate retention windows.
React the peptide with a reagent that will selectively label the terminal amino acid. Hydrolyse the protein. Determine the amino acid by chromatography and comparison with standards. There are many different reagents which can be used to label terminal amino acids. They all react with amine groups and will therefore also bind to amine groups in the side chains of amino acids such as lysine - for this reason it is necessary to be careful in interpreting chromatograms to ensure that the right spot is chosen. Two of the more common reagents are Sanger's reagent (1-fluoro-2,4-dinitrobenzene) and dansyl derivatives such as dansyl chloride. Phenylisothiocyanate, the reagent for the Edman degradation, can also be used. The same questions apply here as in the determination of amino acid composition, with the exception that no stain is needed, as the reagents produce coloured derivatives and only qualitative analysis is required. So the amino acid does not have to be eluted from the chromatography column, just compared with a standard. Another consideration to take into account is that, since any amine groups will have reacted with the labelling reagent, ion exchange chromatography cannot be used, and thin-layer chromatography or high-pressure liquid chromatography should be used instead.
== F == facilitated diffusion – FADH – FADH2 – fat – feedback inhibition – Fehling solution – female – fermentation (biochemistry) – fetus – Fick's law of diffusion – fitness – fitness landscape – flagellum – flavin adenine dinucleotide – flavine – flaviviridae – flower – fluid mosaic model – food web – foot and mouth disease – fossil – Francis Crick – Francis Galton – free energy – fundamental niche – fungi –
In a randomized, controlled trial 12 healthy volunteers ingested 200 mL of either grapefruit juice or water three times daily for five days. On the fourth day 10 mg of oxycodone hydrochloride were administered orally. Analgesic and behavioral effects were reported for 12 hours and plasma samples were analyzed for oxycodone metabolites for 48 hours. Grapefruit juice increased the mean area under the oxycodone concentration-time curve (AUC(0-∞)) by 1.7 fold, the peak plasma concentration by 1.5-fold and the half-life of oxycodone by 1.2-fold as compared to water. The metabolite-to-parent ratios of noroxycodone and noroxymorphone decreased by 44% and 45% respectively. Oxymorphone AUC(0-∞) increased by 1.6-fold but the metabolite-to-parent ratio remained unchanged. Quetiapine (Seroquel) Repaglinide (Prandin) Sirolimus (Rapamycin, Rapamune) Tamoxifen (Nolvadex): Tamoxifen is metabolized by CYP2D6 into its active metabolite 4-hydroxytamoxifen. Grapefruit juice may potentially reduce the effectiveness of tamoxifen. Trazodone (Desyrel): Little or no interaction with grapefruit juice. Verapamil (Calan SR, Covera HS, Isoptin SR, Verelan): atrioventricular conduction disorders. Warfarin (coumadin) Zolpidem (Ambien): Little or no interaction with grapefruit juice
== Chemistry == Lercanidipine is used in form of the hydrochloride, which is a slightly yellow crystalline powder and melts at 197 to 201 °C (387 to 394 °F) in crystal form I or 207 to 211 °C (405 to 412 °F) in crystal form II. It is readily soluble in chloroform and methanol, but practically insoluble in water. This high lipophilicity (compared to older dihydropyridines) is intentional because it causes the substance to bind to lipid membranes, allowing for a longer duration of action. The lercanidipine molecule has one asymmetric carbon atom. While the S-enantiomer is more effective than the R-enantiomer, marketed formulations contain a 1:1 mixture of both (i.e., the racemate).
=== Prenatal and newborn screening === Checking for hemoglobinopathies begins during pregnancy, with a prenatal screening questionnaire which includes, among other things, a consideration of health issues in the child's parents and close relatives. During pregnancy, genetic testing can be done on samples taken of fetal blood, of amniotic fluid, or chorionic villus sampling. A routine heel prick test, in which a small sample of blood is collected a few days after birth, can detect some forms of hemoglobinopathy.
Sources: en.wikipedia.org
=== Available forms === Bicalutamide is available for the treatment of prostate cancer in most developed countries, including over 80 countries worldwide. It is available in 50 mg, 80 mg (in Japan), and 150 mg tablets for oral administration. The drug is registered for use as a 150 mg/day monotherapy for the treatment of LAPC in at least 55 countries, with the U.S. being a notable exception where it is registered only for use at a dosage of 50 mg/day in combination with castration. No other formulations or routes of administration are available or used. All formulations of bicalutamide are specifically indicated for the treatment of prostate cancer alone or in combination with surgical or medication castration. Due to the low water solubility of bicalutamide, bicalutamide in oral bicalutamide tablets is micronized to ensure small and consistent particle sizes and optimize oral bioavailability. A combined formulation of bicalutamide and the GnRH agonist goserelin in which goserelin is provided as a subcutaneous implant for injection and bicalutamide is included as 50 mg tablets for oral ingestion is marketed in Australia and New Zealand under the brand name ZolaCos CP (Zoladex–Cosudex Combination Pack).
=== 30 December === Thirty-five people were killed in an RSF drone strike on Dalang. The RSF and the SPLM-N (al-Hilu) seized the Al-Taqatu’ junction in South Kordofan, effectively cutting the main highway between Kadugli and Dalang. Both forces also seized SAF garrisons in Al-Taqatu’, Al-Balf, and Hajar Daliba.
Point-of-care testing (POCT), also called near-patient testing or bedside testing, is defined as medical diagnostic testing at or near the point of care—that is, at the time and place of patient care. This contrasts with the historical pattern in which testing was wholly or mostly confined to the medical laboratory, which entailed sending off specimens away from the point of care and then waiting hours or days to learn the results, during which time care must continue without the desired information.
Another idea to increase morphine availability is proposed by the ICOS, who suggest, through their proposal for Afghan Morphine, that Afghanistan could provide cheap pain relief solutions to emerging countries as part of a second-tier system of supply that would complement the current INCB regulated system by maintaining the balance and closed system that it establishes while providing finished-product morphine to people in severe pain who are unable to access opiates under the current system.
Sources: en.wikipedia.org
Counterfeit medicinal drugs include those with less or none of the stated active ingredients, with added, sometimes hazardous, adulterants, substituted ingredients, completely misrepresented, or sold with a false brand name. Otherwise, legitimate drugs that have passed their date of expiry are sometimes remarked with false dates. Low-quality counterfeit medication may cause any of several dangerous health consequences, including side effects or allergic reactions, in addition to their obvious lack of efficacy due to having less or none of their active ingredients. Since counterfeiting is difficult to detect, investigate, quantify, or stop, the quantity of counterfeit medication is difficult to determine. In 2003, the World Health Organization cited estimates that the annual earnings from substandard and/or counterfeit drugs were over US$32 billion. The considerable difference between the cost of manufacturing counterfeit medication and price counterfeiters charge is a lucrative incentive. Fake antibiotics with a low concentration of the active ingredients can do damage worldwide by stimulating the development of drug resistance in surviving bacteria. Courses of antibiotic treatment which are not completed can be dangerous or even life-threatening. If a low-potency counterfeit drug is involved, completion of a course of treatment cannot be fully effective. Counterfeit drugs have even been involved in clinical drug trials. Several technologies may prove helpful in combating the counterfeit drug problem.
Solanum pimpinellifolium, commonly known as the currant tomato or pimp, is a wild species of tomato native to Ecuador and Peru but naturalized elsewhere, such as the Galápagos Islands. Its small fruits are edible, and it is commonly grown in gardens as an heirloom tomato, although it is considered to be wild rather than domesticated as is the commonly cultivated tomato species Solanum lycopersicum. Its genome was sequenced in 2012.
In addition to oral activity, 17α-alkylation also confers a high potential for hepatotoxicity, and all 17α-alkylated AAS have been associated, albeit uncommonly and only after prolonged use (different estimates between 1 and 17%), with hepatotoxicity. In contrast, testosterone esters have only extremely rarely or never been associated with hepatotoxicity, and other non-17α-alkylated AAS only rarely, although long-term use may reportedly still increase the risk of hepatic changes (but at a much lower rate than 17α-alkylated AAS and reportedly not at replacement dosages). In accordance, D-ring glucuronides of testosterone and DHT have been found to be cholestatic. Aside from prohormones and testosterone undecanoate, almost all orally active AAS are 17α-alkylated. A few AAS that are not 17α-alkylated are orally active. Some examples include the testosterone 17-ethers cloxotestosterone, quinbolone, and silandrone, which are prodrugs (to testosterone, boldenone (Δ1-testosterone), and testosterone, respectively), the DHT 17-ethers mepitiostane, mesabolone, and prostanozol (which are also prodrugs), the 1-methylated DHT derivatives mesterolone and metenolone (although these are relatively weak AAS), and the 19-nortestosterone derivatives dimethandrolone and 11β-MNT, which have improved resistance to first-pass hepatic metabolism due to their 11β-methyl groups (in contrast to them, the related AAS trestolone (7α-methyl-19-nortestosterone) is not orally active). As these AAS are not 17α-alkylated, they show minimal potential for hepatotoxicity.
Sources: en.wikipedia.org
It measures the presence and amount of one or more compounds in a liquid sample. Separation occurs in a column, and detection produces a signal proportional to concentration. Identification usually requires comparison with a known reference standard under the same conditions.
In most cases the sample is consumed or altered during analysis, though some detectors are non-destructive. Fractions can be collected after separation for further study. Repeated testing therefore requires additional sample.
Run times range from under a minute for fast methods to over an hour for complex separations. Sample preparation, equilibration, and data review add time. Throughput depends on instrument configuration and method requirements.
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.